IBM Opens Manufacturing Facility for Power Systems, System z in Poughkeepsie

IBM has opened a new $30 million manufacturing facility at its Poughkeepsie site to produce high-end Power Systems servers and the next generation of System z mainframes.
 
The 56,000-square-foot facility, built inside an existing structure at IBM's 400-acre site in Poughkeepsie, features several innovations to conserve energy and improve manufacturing processes, IBM says. 
 
"The new manufacturing facility in Poughkeepsie reflects IBM innovation in the design, testing, and assembly of its mainframes and high-end servers," notes Mike Desens, Poughkeepsie senior location executive for the IBM Systems & Technology Group. "And it underscores our reliance on the skills and talents of our workforce, as well as a long-term commitment to a continuing presence in New York State and the Mid-Hudson Valley," he adds.
 
The new facility, in planning for more than three years, is designed more like a data center than a warehouse, with a strong emphasis on innovation and efficiency. The facility's features include:
  • A closed loop system that circulates chilled water throughout the facility for air conditioning, systems cooling and other functions. A similar system is in use throughout the Poughkeepsie site.
  • The new facility has a chilled water cooling capacity of 1,700 tons -- constantly circulating through pipes, air conditioning, servers and cooling sources -- and also uses localized system cooling through IBM's unique "Cool Blue" Rear Door Heat eXchangers. An energy-saving technology offered by IBM, this solution features a passive water-cooled door which mounts to the back of IBM systems to cool computer equipment exhaust air before it re-enters the data center operating environment.
  • Thermodynamically-sound hot and cold aisles in the test area, placing systems front to front and back to back to maximize air flow and energy efficiency. The facility is designed so that the systems use fans to intake cool air in the front and then exhaust hot air out the back of the system. This optimizes data center thermal flow dynamics to eliminate hot spots and reduce energy consumption in the facility.
  • The latest environmental practices in temperature control and lighting, such as high-efficiency fluorescent lighting and occupancy sensors, to further reduce energy consumption.
  • The plant also is ergonomically designed and built with noise reduction, cleanliness, and material handling features for an improved employee work environment. For example, a new ceiling tile system helps reduce noise with minimal dust retention.
IBM says the facility is designed to handle the next generation of systems and the capacity and flexibility to manufacture future products. The first products for customers are expected to roll off the assembly line later this year.

Comments

Was it good for you, too?Join the discussion » ,but you need to login first before you make comments.

     

    Other Recent Comments

    1. Re: Easy Ways to Trace VSCSI Configuration with AIX

      No Anthony, it's not so obvious. As you see, I've removed first paths and after that I changed vscsi...

      --Andrey Klyachkin

    2. Re: Easy Ways to Trace VSCSI Configuration with AIX

      Thanks, Andrey. Your test shows that if one path is down, then its corresponding VSCSI adapter isn't...

      --Anthony English

    3. Re: Easy Ways to Trace VSCSI Configuration with AIX

      Test with rmpath/cvai:# lspath -l hdisk1 -F parentvscsi0vscsi1# lspath -l hdisk0 -F parentvscsi0vscs...

      --Andrey Klyachkin

    4. Re: IBM Reveals PowerLinux Details and Pricing

      Thanks for the tip, Bill -- much appreciated! (I must say, though, we'll have to wrangle a few Power...

      --Chris Maxcer

    5. Re: IBM Reveals PowerLinux Details and Pricing

      http://www.ibm.com/developerworks/group/tpl

      --Bill Buros

    Google Links

    Sponsored Links

    Featured Links

    MiddleR
    BottomL BottomM BottomR

    © Penton Media, Inc.